Official US store Free shipping Bundle & Save up to 20%
Lemon

Support

Hi-Hat Controller Sensor on Roland TD-17

Wiring, module settings, and tips for the Hi-Hat Controller Sensor when used with the Roland TD-17.

Setup — Hi-Hat Controller Sensor on Roland TD-17

Works

Yes — the Hi-Hat Controller Sensor works as a full hi-hat on the Roland TD-17: variable pedal position.

Continuous Open Closed

Wiring: 1× TRS → the “HH” lead on the dedicated connection cable + 1× TRS (controller) → the “HHC” lead

Continuous hi-hat control. Supports VH-11 and VH-10 pad types.

Cable routing

  1. Connect a ¼″ TRS cable from the hi-hat pad to the lead labeled “HH” on the dedicated connection cable.
  2. Connect a ¼″ TRS cable from the hi-hat controller to the lead labeled “HHC”. The Setup Guide wires the stock VH-10 the same way: HH plug to its TRIGGER OUT jack, HHC plug to its CONTROL OUT jack.

Module settings

  1. With your foot off the pedal, power on the TD-17, then loosen the clutch screw so the hi-hat rests naturally on the motion sensor unit.
  2. Press [SETUP], turn the dial to select "Hi-Hat Settings", then press [ENTER].
  3. Turn the dial to set Pad Type to VH11 (or VH10).
  4. Set the resting gap with the clutch while reading the on-screen meter — a Lemon hi-hat has no offset adjustment screw, so raise or lower the cymbal until the meter centres.

Tips

  1. Continuous pedal control provides smooth open-to-closed transitions.
Hi-Hat Controller Sensor also fits 70 other drum modules — see setup

Support contact

Have a question? Read the FAQ. Need manual help? Email support.