Hi-Hat Controller Sensor on Roland TD-15
Setup — Hi-Hat Controller Sensor on Roland TD-15
WorksYes — the Hi-Hat Controller Sensor works as a full hi-hat on the Roland TD-15: variable pedal position.
Continuous
Open
Closed
Wiring: 1× TRS → HI-HAT connector on the DB-25 cable snake + 1× TRS → HHC connector on the DB-25 cable snake
Continuous hi-hat control via the cable snake.
Cable routing
- Connect a ¼″ TRS cable from the hi-hat pad to the HI-HAT connector on the DB-25 cable snake.
- Connect a ¼″ TRS cable from the hi-hat controller pedal to the HHC connector on the DB-25 cable snake.
Module settings
- In the DRUM KIT screen, press [MENU], scroll to the SYSTEM icon, press [F3] (SYSTEM), select "Pad Settings", then press [F3] (ENTER).
- Press [F1] (TYPE) and use the cursor buttons to select "HH".
- Turn the value dial to set Pad Type to VH-11.
- Press [F2] (BASIC) and set Sensitivity and Threshold for the hi-hat.
Tips
- Continuous pedal control provides smooth open-to-closed transitions.
- Calibrate the hi-hat offset after connecting for accurate pedal response.