Support
Hi-Hat Controller Sensor on Roland V31
Setup — Hi-Hat Controller Sensor on Roland V31
WorksYes — the Hi-Hat Controller Sensor works as a full hi-hat on the Roland V31: variable pedal position.
Continuous
Open
Closed
Wiring: 1× TRS → HI-HAT connector on the DB-25 cable snake + 1× TRS → HHC connector on the DB-25 cable snake
Continuous hi-hat control via the cable snake.
Cable routing
- Connect a ¼″ TRS cable from the hi-hat pad to the HI-HAT connector on the DB-25 cable snake.
- Connect a ¼″ TRS cable from the hi-hat controller pedal to the HHC connector on the DB-25 cable snake.
Module settings
- Press the [MENU] button.
- Use the cursor buttons to select "SYSTEM" -> "TRIGGER", then press [ENTER].
- Press the [F4] (HI-HAT) button to open the TRIGGER - HI-HAT screen.
- Use the dial to set the Trig Type to VH-11 (or VH-10).
- While reading the on-screen meter, adjust the hi-hat's offset adjustment screw until the indicator is centered.
Tips
- Continuous pedal control provides smooth open-to-closed transitions.
- Calibrate the hi-hat offset after connecting for accurate pedal response.