Setup — Hi-Hat Controller Sensor on Roland TD-10

Works

Yes — the Hi-Hat Controller Sensor works as a full hi-hat on the Roland TD-10: variable pedal position.

Continuous Open Closed

Wiring: 1× TRS → HI-HAT input on the rear panel + 1× TRS (controller) → HH CTRL input on the rear panel

Continuous hi-hat control with full pedal expression.

Cable routing

  1. Connect a ¼″ TRS cable from the hi-hat pad to the HI-HAT input on the rear panel.
  2. Connect a ¼″ TRS cable from the hi-hat controller to the HH CTRL input on the rear panel.

Module settings

  1. Press [SETUP], then press [F1 (TRIG)], and then press [F1 (BANK)].
  2. Use [CURSOR] to move off the BANK field, then strike the hi-hat pad — the cursor moves to that pad's trigger number.
  3. Set the trigger type to PD7 — the TD-10's trigger-type list has no hi-hat values. Pedal position is read from the HH CTRL jack, not from the trigger type.

Tips

  1. Continuous pedal control provides smooth open-to-closed transitions.
  2. After turning on the power, do not press the hi-hat control pedal until the drum kit name appears in the display — otherwise open/close operations cannot be performed correctly.
Hi-Hat Controller Sensor also fits 70 other drum modules — see setup