Support
Hi-Hat Controller Sensor on Roland TD-50X
Setup — Hi-Hat Controller Sensor on Roland TD-50X
WorksYes — the Hi-Hat Controller Sensor works as a full hi-hat on the Roland TD-50X: variable pedal position.
Continuous
Open
Closed
Wiring: 1× TRS → HI-HAT input on the rear panel + 1× TRS → HH CTRL input on the rear panel
Continuous hi-hat control with granular pedal curve adjustment. Same as TD-50.
Cable routing
- Connect a ¼″ TRS cable from the hi-hat pad to the HI-HAT input on the rear panel.
- Connect a ¼″ TRS cable from the hi-hat controller pedal to the HH CTRL input on the rear panel.
Module settings
- Press the [TRIGGER] button.
- Press the PAGE [UP] button several times to display the topmost page.
- Press the [F4] (HI-HAT) button to open the TRIGGER - HI-HAT screen.
- Use the [-] [+] buttons or the dial to set the Trig Type to VH11 (or VH13 / VH10).
- Press the [F5] (OFFSET) button, loosen the clutch so the top hi-hat rests on the sensor, then follow the screen to set the VH Offset.
Tips
- Calibrate the VH offset: loosen the clutch, let the hi-hat rest on the motion sensor, and adjust the offset screw until the on-screen indicator is centered.
- Pedal curve is adjustable for fine control over the open-to-closed gradient.