13" Triple-Zone Crash/Ride on Roland TD-07

Wiring, module settings, and tips for the 13" Triple-Zone Crash/Ride when used with the Roland TD-07.

Setup — 13" Triple-Zone Crash/Ride on Roland TD-07

Reduced — 2-zone ride

The 13" Triple-Zone Crash/Ride works on your Roland TD-07 with reduced zones.

Bell Bow Edge

Wiring: 1× TRS (Cable 2) → RIDE connector on the DB-25 cable snake — bow + bell

Full 3-zone is not supported — this module has a single Ride input. Connect Cable 2 (bow + bell) from the Lemon 3-zone ride cymbal; bow and bell zones both work through this cable.

Cable routing

  1. Connect Cable 2 (the bow + bell cable) from the Lemon 3-zone ride cymbal to the RIDE input.

Module settings

  1. Press [SETUP] > Pad Settings and navigate to the RIDE input.
  2. Set the pad type to a 2-zone ride (CY-12R/C size) or a 2-zone crash — the TD-07 has a single Ride input and does not expose a 3-zone ride pad type.
  3. Adjust Sensitivity, Threshold, and Crosstalk so bow and bell strikes register cleanly.
  4. In your kit, load a ride-bow sample on the bow zone and a ride-bell sample on the second zone — bow and bell hits will play through Cable 2 as expected.

Tips

  1. Cable 2 delivers bow and bell — the two most-used zones for ride playing.
  2. Full simultaneous 3-zone operation is not available on this module — only one cable can be connected at a time.