Setup — 15" Dual-Zone China on Roland V71

Works

Yes — the 15" Dual-Zone China works as a full 2-zone crash on the Roland V71: bow + edge.

Bow Edge

Wiring: 1× TRS → CRASH1 or CRASH2 input on the rear panel

Dual-zone crash triggering: bow (tip) and edge (ring) respond independently via the single TRS connection. Choke works by grabbing the cymbal edge. The V-71 supports Roland CY-series 2-zone cymbals.

Cable routing

  1. Connect a ¼″ TRS cable from the cymbal to the CRASH1 or CRASH2 input on the rear panel.

Module settings

  1. Press the [TRIGGER] button.
  2. Press the [F1] (BANK) button to open the TRIGGER - BANK screen.
  3. Select the CRASH1 or CRASH2 input (strike the pad or use the cursor buttons).
  4. Use the [-] [+] buttons or the dial to set the trigger type to the model that most closely matches your connected pad (the full trigger-type list is in the module's Data List).
  5. For finer control, press [F3] (BASIC) and adjust Sensitivity on the TRIGGER - BASIC screen.

Tips

  1. Bow and edge zones respond independently.
  2. Choke works by grabbing the cymbal edge.
  3. The DIGITAL TRIGGER IN jacks are for Roland digital pads (CY-18DR) only.
15" Dual-Zone China also fits 73 other drum modules — see setup

Support contact