Support
15" Dual-Zone China on Roland TD-27
Setup — 15" Dual-Zone China on Roland TD-27
WorksThe 15" Dual-Zone China is fully supported on your Roland TD-27.
Bow
Edge
Wiring: 1× TRS → CRASH1 connector on the DB-25 cable snake, or CRASH2 / AUX1 / AUX2 / AUX3 direct jack on the rear panel
Dual-zone crash triggering: bow (tip) and edge (ring) respond independently via the single TRS connection. Choke works by grabbing the cymbal edge. The TD-27 supports Roland CY-series 2-zone cymbals.
Cable routing
- Connect a ¼″ TRS cable from the cymbal to the CRASH1 connector on the DB-25 cable snake.
- For additional cymbals, connect to the CRASH2, AUX1, AUX2, or AUX3 input on the rear panel.
Module settings
- Press [SETUP] > Pad Settings > Trig Type.
- Navigate to the CRASH1, CRASH2, or AUX input.
- Set the trigger type to CY-12C or CY-14C depending on your cymbal size.
Tips
- Bow and edge zones respond independently.
- Choke works by grabbing the cymbal edge.
- The 3 DIGITAL TRIGGER IN (USB) jacks are for Roland digital pads only.