Free Shipping on All Orders
Lemon

Support

T950 13"x13" Floor Tom on Alesis DM7X

Wiring, module settings, and tips for the T950 13"x13" Floor Tom when used with the Alesis DM7X.

Setup — T950 13"x13" Floor Tom on Alesis DM7X

Works

The T950 13"x13" Floor Tom is fully supported on your Alesis DM7X.

Head Rim

Wiring: 1× TRS per tom → Tom1, Tom2, Tom3 connectors on the cable snake

The tom connectors on the cable snake support dual-zone (head + rim) triggering via center piezo and rim switch.

Cable routing

  1. Connect a 1/4" TRS cable from each tom pad to the Tom1, Tom2, or Tom3 connector on the cable snake.

Module settings

  1. Access the trigger settings menu on the module.
  2. Select the Tom input and adjust Sensitivity and Threshold if available.

Tips

  1. Head triggers from the center piezo, rim triggers from the rim switch.
  2. Both zones respond independently on the TRS connection (tip = head, ring = rim).